Equipment
What to do when a pool pump won't prime
If a pool pump will not prime, stop it before it runs dry, then check the water level, baskets, valves, and the lid seal. This guide is a careful sequence for a typical residential pump. If you have to take the plumbing apart or the breaker trips, call a technician.
In this guide
Step by step
-
Stop the pump if it is running dry
A pump that cannot fill with water will not move water, and the seal and impeller can be damaged quickly. Turn it off at the timer or the breaker and give the motor a few minutes to sit before you open anything.
-
Check the water level and the baskets
The water needs to be high enough to flow into the skimmer opening. If the level is low, add water first. Empty the skimmer basket and the pump basket. A packed basket can starve the pump of water.
-
Confirm the valves are open
Look at the suction and return valves and set them for normal circulation. After a winter close, a valve may still be shut, or a plug may still be in a suction or return line. Do not start the pump against a closed suction line.
-
Inspect the pump lid and O-ring
Air leaking in at the lid is a common reason a pump will not prime. Take the lid off (with the power off), clean the O-ring and the groove, check for cracks or a flattened ring, and seat the ring so it is not pinched. Close the lid firmly. If the ring is dry, a small amount of a lubricant the manufacturer allows can help it seal; do not use a product the manual warns against.
-
Fill the strainer pot and restart
Fill the pump strainer with a hose until it is full, put the lid back on, and start the pump. Watch the pot. It should stay full, and you should soon see water at the returns. If the pot empties or fills with air, shut the pump off again.
-
If it still will not prime, stop and look for air leaks
Check the lid again, the unions on the suction side, and any valves or plugs from winterizing. A cracked pump housing or a bad union gasket can also pull air. If you cannot find a simple cause, or if you would have to take the plumbing apart, stop and call a technician rather than running the pump dry in repeated bursts.
When to call a pro
Call a pool technician if the pump still will not prime after you have checked the water level, baskets, valves, and lid; if you see a crack, a leak, or damaged wiring; if the breaker trips; or if the pool was winterized and you do not want to reopen the plumbing yourself. Running a dry pump longer will not fix it.
Questions owners often ask
How do I know the pump has primed?
The strainer pot should fill and stay full of water, the motor should sound steady rather than loud and rattling, and you should see a firm return flow at the jets.
Why did this start after I opened the pool?
A winter plug may still be in a line, a valve may still be closed, or the pump lid may not be sealed after you drained the equipment. Work through the steps above before you run the pump for long.
Can I keep restarting the pump until it catches?
Only in short attempts after you have filled the pot and checked the lid and valves. Repeated dry running can ruin the seal. If it does not catch quickly, stop and look for an air leak or a blockage.
Is this something I should always hire out?
If you are comfortable checking water level, baskets, lids, and valves, the first steps are reasonable to try. If you have to open unions, find a hidden leak, or work on electrical connections, call a technician.